Blocked inlet |
Clean inlet swarf arrestor |
Afterfilter is blocked |
Change Afterfilter – (recommended every 3-6 months) |
Unit needs servicing |
Contact Filtermist Local Distributor (recommended Service intervals of 6 months or 1000
hours – whichever earlier) |
Kinks in ducting |
Ensure no kinks in ducting
Ensure that the ducting has no “U” bends without an oil drainaway at the bottom of the “U”,
as this will cause oil to build up and block airflow |
Pre-filter blocked |
If unit has a pre-filter, to check that it is not the pre-filter blocking the air, remove
to test the airflow; if the airflow returns to correct levels, order replacement pads, or
clean the recyclable pre-filter using a parts washer |
Equipment requiring extraction not adequately enclosed |
The unit will have an especially difficult job, and must not usually be used on high
velocity applications such as grinding, and should be tested to ensure the unenclosed
equipment’s mist is safely extracted |
Drum spinning the wrong direction |
Check the rotation of the drum from above or below the Filtermist unit. Ensure the red directional arrow is followed when the unit is speeding down or speeding up (as you cannot tell which direction the drum is spinning when the unit is operating at full speed). If the drum is turning in the wrong direction, change two of the three phase wires around (from L1, L2, L3). |